How to Buy?

Feature
• Small weight modular design and very easy to install and operate
• It tests all battery types of 1.2V, 2V, 6V and 12V
• Simple wireless communication between battery string and PC software
• Simultaneously monitor cell voltage, string voltage, current and ambient temperature
• Data auto saving in PC, no need for data transfer
• Individual operation to reflect different aspect of battery status
• Compatible with PITE 3970, PITE 3980 and PITE 3990 during battery charging or discharge
• Suitable for battery system of 12V, 24V, 48V, 110V, 220V and 380V
• One logging modular (cell DAC) is connected with multiple batteries, save your time and money
• Easy expended for more extra modules with simple plug-in and data setting 
• Could be used as temporary voltage monitoring or as permanent battery monitor
• Direct powered by battery, no need for extra power supply
• User-friendly PITE DataView software and for battery recording and testing data management
• Monitor interval is customer programmed for real time monitor and report generation
Technical Specification
|
Item |
Testing range |
Accuracy |
|
Cell voltage |
0~16V |
±0.5% |
|
String voltage |
0~450V (customized) |
±0.5% |
|
Current testing |
0~1000A (customized current sensor) |
±1% |
|
Temperature measurement |
-25~ |
± |
|
Power supply |
Cell DAC |
DC12V±15% (Supplied by battery) |
|
String DAC |
DC12V±15% (Supplied by battery) |
|
|
Wireless communication modular |
DC5V±5% (Supplied by PC via USB) |
|
|
Monitoring software |
PITE PC software with data management function |
|
|
Communication |
FSK |
|
|
Communication distance |
100m (not blocked) |
|
|
Communication frequency |
433MHz |
|
|
Weight |
0.15 kg/per modular |
|
|
Size |
121×113×40 mm |
|
|
Warning for |
Communication disconnection, Over voltage and Low voltage |
|
|
Working environment |
Temperature: 0~55℃ Relative humility: ≤85%RH |
|
|
Data sampling interval |
0.1 seond/point |
|
|
Safety standard |
CE marking |
|
Battery Management Software

Composition
Standard PITE 3926C unit composes of the followed parts:
Cell DAC>>>
Cell DAC (Data Acquisition Case) is for monitoring voltage of each cell. With 2 color coded serial ports, each Cell DAC could be connected with 4 cells of 12V (or 6V), and 12 cells of 2V (or 1.2V). For different battery system, number of cell DACs will vary accordingly. For example in 48V system in telecom, it will need 2 Cell DACs if it is 24 cells of 2V.
Cell DAC is powered by batteries with DC12V±15%. With built-in wireless communication module, value of cell voltage could be received directly in PC.
String DAC>>>
Connected with two ends of battery string, String DAC is for monitoring string voltage, string current
and ambient temperature. Each String DAC will come with a customized current sensor for testing string current. Each PITE 3926C Data Logger will only need ONE String DAC which also include built-in communication module for wireless communication.
|
Communication terminal and RS232-USB converter>>> Computer (Optional)>>> NOTE: All above standard units also include 1 string DAC, 1 communication terminal, 1 RS232-USB converter and PITE 3926C DataView software. |
|
Related Products