PITE 3980 Battery Load Bank_General

PITE 3980 Battery Load Bank_General

PITE 3980 series DC load units consist of various models covering almost all areas for battery discharge: telecom, power industry, 380V UPS system and so on. With its optional Data Acquisition Case (DAC), you will have a real-time monitoring for the whole process of discharge with wireless communication in PC. They are portable, easy going and cost effective.

PITE 3980 series Battery Load Banks include various models for the following applications:

¨         Telecom

¨         Power

¨         Telecom & Power

¨         380V UPS

This page is just general info of PITE 3980 Battery Load Bank, for detailed info of each relevant models, please click HERE.

Feature

¨        Small weight, portable unit with carrying case, convenient for onsite test

¨        Optional wireless DAC enables its PC monitoring both for discharging and charging

¨        It sets 4 conditions for auto shut-down of discharge, secured and time-saving

¨        Continued discharge available when previous discharge is stop abnormally

¨        Parallel connection of two units for mass discharge

¨        Real-time display of voltage for each cell with DAC

¨        Accurate data results and vivid waveforms

¨        Auto sorting for lag-out batteries during discharging

¨        AC & DC power supply modes for different needs

¨        Integrated functions for displaying, controlling and discharging                       

¨        Safe circuits avoids damage to battery when testing

¨        Direct USB drive for convenient data transfer to PC

¨        Powerful management software for data analyzing and report printing

¨        Warning info, dynamic discharge and static discharge data auto-saving

¨        Various models to meet almost all your application in either telecom or power utility

Mains Voltage

1). AC 220V/110V, 50/60Hz;

2). DC (from battery discharged)

Discharging Current

Accuracy: 1%    Resolution: 0.1A or 0.5%

Discharge voltage range

48V: 10-55.2V      110V*: 10V-126.5V  

220V: 10-253V     380V: 10-437V     

Voltage Accuracy

0.5%

Sampling Interval

5s --1min

LCD Display

128*64 pixel

Temperature

040          

Humidity

5%90% Relative humidity

Safety standard

CE market, EMC standard

Dimension & Weight

(main unit)*

 

400*177*280 mm (Size: S, 11kg)

520*202*355 mm (Size: M, 16kg)

555*225*435 mm (Size: L, 21kg)

603*400*740 mm (Size: XL, 43kg)      


 